1.
Chinese Journal of Hepatobiliary Surgery ; (12): 124-128, 2023.
Article in Chinese | WPRIM | ID: wpr-993293

ABSTRACT

Objective:To investigate the protective role of extracellular signal-regulated kinase (ERK) signaling pathway in the process that vasonatrin peptide (VNP) reduces hepatic ischemia-reperfusion injury in rats.Methods:Twenty SD rats, weighting 200-250 g, were randomly divided into four groups and each group has five rats. The four groups were sham operation group (S group), ischemia-reperfusion group (I/R group), VNP group (V group) and PD98059+ VNP group (P+ V group). In the rat model of hepatic warm ischemia and reperfusion, the hepatic artery and portal vein of the left lobe and middle lobe of the liver were clamped with arterial clamp for 45 min followed by reperfusion for 120 min. In the V group, VNP (50 μg/kg) was injected 10 minutes before ischemia. In the P+ V group, PD98059 (2 mg/kg) was injected 20 min before VNP injection followed by VNP administration and I/R treatment. The serum levels of alanine amino transaminase (ALT), aspartate amino transferase (AST), tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β) and the superoxide dismutase (SOD) in liver tissue homogenate and malondialdehyde (MDA) were measured. The histopathology of liver tissue was observed. The contents of p-ERK1/2 were detected by Western blot.Results:Compared with S group, in I/R group and P+ V group the serum levels of ALT [(489.65±11.22), (333.05±24.77) vs. (33.78±4.88) U/L], AST [(651.43±14.99), (503.18±21.48) vs. (154.84±12.32) U/L], TNF-α [(12.83±1.09), (9.64±0.57) vs. (2.11±0.11) ng/L], IL-1β [(7.19±0.62), (5.12±0.22) vs. (1.10±0.49) ng/L], MDA [(8.00±0.88), (5.60±1.01) vs. (2.76±1.29) μmol/mg] increased, while SOD [(54.89±10.60), (68.85±8.33) vs. (126.10±15.63) nmol/mg]decreased (all P<0.05). The histopathology of liver tissue revealed that liver structure damaged more seriously in I/R group and P+ V group. Western blot analysis showed that p-ERK1/2 decreased significantly in I/R group and P+ V group. Compared with I/R group, ALT, AST, MDA, TNF-α and IL-1β decreased significantly and SOD increased significantly in V group (all P<0.05). The histopathology of liver tissue revealed that liver structure was damaged slightly, and p-ERK1/2 increased significantly in V group compared with I/R group ( P<0.05). Conclusion:VNP can significantly reduce hepatic ischemia-reperfusion injury through activation of p-ERK1/2 signaling pathway and inhibition of hepatocyte inflammatory response.

2.
Chinese Journal of Medical Instrumentation ; (6): 22-25, 2021.
Article in Chinese | WPRIM | ID: wpr-880416

ABSTRACT

OBJECTIVE@#In the context of coronavirus disease 2019 (COVID-19) pandemic, the subject was designed to develop a new tracheal intubation device based on magnetic navigation technology to improve the success rate of tracheal intubation and reduce the risk of occupational exposure of medical staff.@*METHODS@#The new tracheal intubation device was designed with the uniqueness of the magnetic field environment and magnetic steering of magnetic navigation technology. And preliminary magnetic navigation tracheal intubation experiments were performed on the tracheal intubation simulator.@*RESULTS@#Magnetic navigation tracheal intubation can successfully implement tracheal intubation, and the time required is lower than that of traditional laryngoscopy.@*CONCLUSIONS@#The tracheal intubation based on magnetic navigation technology is feasible, with high efficiency and easy operation. That is expected to be widely used for tracheal intubation during treatment of patients outside the hospital in the future. At the same time, magnetic navigation endotracheal intubation technology will be the key technology for the development of endotracheal intubation robots.


Subject(s)
Humans , COVID-19/therapy , Equipment Design , Feasibility Studies , Intubation, Intratracheal , Magnetic Phenomena , SARS-CoV-2 , Technology
3.
Chinese Journal of Digestive Surgery ; (12): 544-551, 2020.
Article in Chinese | WPRIM | ID: wpr-865085

ABSTRACT

Objective:To investigate the clinical efficacy of endoscopic magnetic compression bilio-enteric anastomosis for the treatment of biliary obstruction after complex abdominal surgery.Methods:The retrospective and descriptive study was conducted. The clinical data of 3 patients with biliary obstruction after complex abdominal surgery who were admitted to the First Affiliated Hospital of Xi′an Jiaotong University between January 2012 and December 2019 were collected. There were 2 males and 1 female, aged from 27 to 57 years, with a median age of 56 years. The 3 patients underwent endoscopic magnetic compression bilio-enteric anastomosis to complete internal drainage of bile ducts after several unsuccessful endoscopic or interventional therapy. Observation indicators: (1) surgical situations; (2) postoperative situations; (3) follow-up. Follow up using outpatient examination was performed to detect the biliary stent, liver function and patency of anastomotic stoma up to December 2019.Results:(1) Surgical situations: all the 3 patients underwent successful endoscopic magnetic compression bilio-enteric anastomosis, including 2 cases with magnetic compression choledochoduodenal anastomosis and 1 case with magnetic compression choledochojejunostomy. The length of biliary stricture, length and width of magnetic device subsidiary magnet/patent magnet, time of magnetic compression for the 3 patients were 7.1 mm, 3.0 mm, 2.0 mm, 7 mm/8 mm, 6 mm/6 mm, 5 mm/5 mm, 130 minutes, 90 minutes, 75 minutes, respectively. (2) Postoperative situations: the time to biliary tract recanalization after operation for the 3 patients were 15 days, 8 days, 9 days, respectively. None of the patients encountered gastrointestinal perforation, hemorrhage or infection. (3) Follow-up: the biliary stents were inserted into the anastomotic stoma for the 3 patients after biliary tract recanalization, including a catheter of percutaneous transhepatic cholangiodrainage (PTCD) with 12 Fr size, a biliary plastic stent with 7 Fr size, a catheter of PTCD with 14 Fr size, respectively. The biliary stents were removed after 17 months, 2 months, and 6 months from the 3 patients, respectively. The 3 patients were followed up for 40 months, 20 months, and 5 months respectively after removing biliary stents, and the concentration of total bilirubin, concentration of aspartate aminotransferase, concentration of alanine aminotransferase for the 3 patients were 5-19 μmol/L, 25-40 U/L, and 20-35 U/L, respectively. The results of ultrasonic examination or magnetic resonance cholangiopancreatography examination showed that no intra-hepatic bile duct dilation or stricture of choledochojejunostomy was found within the 3 patients. One of the 3 patients was hospitalized for biliary tract infection after 37 months from removing biliary stents, and the results of ultrasonic examination or magnetic resonance cholangiopancreatography examination showed intrahepatic cholelithiasis. The cholelithiasis was removed under endoscopy and stricture of choledochojejunostomy was not found within patient by the endoscopic examination or cholangiography examination.Conclusion:The endoscopic magnetic compression bilio-enteric anastomosis is a safe and feasible technique for the treatment of biliary obstruction after complex abdominal surgery with good long-term effects.

4.
Chinese Journal of Medical Instrumentation ; (6): 17-20, 2019.
Article in Chinese | WPRIM | ID: wpr-772576

ABSTRACT

A motion unit for sucking robot with a stable motion, convenient operation and process simulation is introduced. The key parameters and process data of the sucking operation were obtained from the clinical work, which provided the basis for the design of the sucking robot motion unit. According to the points of sucking action, robotic thumb, forefinger and metacarpophalangeal joints were used to grip the suction tube, and the servo and arm structure were used to simulate the motion of the wrist and elbow to complete the rotation and push of the sputum suction tube. The feasibility is verified through the advanced sputum suction training model. The movement unit is stable in movement, and can smoothly complete the clamping, feeding, back off protection and rotating tube removal of the sputum suction tube, so as to achieve effective sputum suction.


Subject(s)
Catheterization , Intubation, Intratracheal , Robotics , Suction
5.
Chinese Journal of Medical Instrumentation ; (6): 11-13, 2018.
Article in Chinese | WPRIM | ID: wpr-774481

ABSTRACT

A biliary contrast agents pushing device, including a syringe pushing system and a remote controller is introduced. The syringe pushing system comprises an injector card slot, a support platform and an injection bolus fader. A 20 mL syringe can be fitted on the syringe pushing system and kept with the ground about 30 degree. This system can perform air bubble pumping back and contrast agents bolus injection as well as speed adjustment. Remote controller is an infrared remote control which can start and stop the syringe pushing system. With this device, the remote controlled cholangiography technology can be achieved, which can not only protect doctors from X-ray radiation but also improve the traditional T-tube cholangiography and the contrast effect, reduce postoperative complications in patients as well. The application of this device will improve the current diagnosis and treatment system, the device will benefit the majority of doctors and patients.


Subject(s)
Humans , Contrast Media , Injections , Postoperative Complications , Syringes
6.
Organ Transplantation ; (6): 200-204, 2018.
Article in Chinese | WPRIM | ID: wpr-731729

ABSTRACT

Objective To develop a pulling device using magnetic positioning to optimize the procedures of repairment of donor liver from organ donation . Methods The pig liver specimens were used to measure the pull force of repairment of donor liver, magnetic spiderman was developed based on the measurement results. The magnetic spiderman was applied to simulate the repairment of donor liver from organ donation on the pig liver specimens. The effectiveness of magnetic spiderman was also evaluated. Results The pulling force was required all less than 2 N during the repairment of donor liver. The magnetic spiderman was successfully manufactured. The magnets of magnetic spiderman could generate 3 N magnetic forces with paramagnetic basin of hepatic repairment. The self-retraction pull wire of the magnetic spiderman could provide 2.5 N pulling forces. The magnetic spiderman was successfully applied to the simulated experiment of repairment of donor liver from organ donation in 6 cases. The operation time was (54±5) min. No clip slippage,displacement and slippage of the base occurred during the operation. With the cooperation of multiple magnetic spidermen,the remaining surgical procedures were performed by one single surgeon except for the vascular ligation. Conclusions The magnetic spiderman has small volume and implements flexible positioning, can perform pulling operation and nottake up operational space. It can effectively optimize the procedures of repairment of donor liver from organ donation and reduce the quantity of surgeons.

7.
Chinese Journal of Medical Instrumentation ; (6): 427-431, 2015.
Article in Chinese | WPRIM | ID: wpr-265598

ABSTRACT

Liver transplantation is the only way to treat end-stage liver disease. In order to overcome the shortage of donor, marginal donors have been used widely, which bring about a series of problems. Machine perfusion can stimulate the circulation in vivo and is beneficial for the protection of liver. It could also improve the graft function and reduce postoperative complications, which makes it a hot spot in recent years. The aim of this study is to summarize the current status and prospects of application of machine perfusion on clinical liver transplantation.


Subject(s)
Humans , Liver , Liver Transplantation , Perfusion , Methods , Tissue Donors
8.
Chinese Journal of Medical Instrumentation ; (6): 437-441, 2015.
Article in Chinese | WPRIM | ID: wpr-265596

ABSTRACT

In recent years, the emergence of single-port laparoscopic technology promoted the development of the technology of laparoscopy, but deficiencies like equipment conflict or lack of triangulation severely hampered the clinical application of this technology. The appearance of single-port laparoscopic flexible instruments makes up for those deficiencies to a great extent. The element is to add a wrist joint to the tip of the instrument to form triangulation and reduce equipment conflict. But this technique is still in an early stage of development. The purpose of this article is to summarize the characteristics and problems of existing flexible single-port laparoscopic instruments, and to provide information for the further improvement, finally the future development was expected.


Subject(s)
Humans , Equipment Design , Laparoscopy
SELECTION OF CITATIONS